Incident ID |
MD00581-3433 |
|
Dam Name |
Volvo Hagerstown Swm |
|
Downstream Hazard Potential |
S |
|
State |
MD |
|
Incident Date |
09/01/2021 |
|
Incident Type |
Non-failure |
|
Incident Driver |
Hydrologic/flooding |
|
Incident Mechanism 1 |
Debris Clogging |
|
Incident Mechanism 2 |
Insufficient Spillway Capacity |
|
Incident Mechanism 3 |
Overtopping |
|
Incident Description |
Undersized spillway, partially plugged, resulted in minor overtopping and emergency response |
|
Named Hydrologic Event |
Hurricane Ida |
|
EAP Enacted (Y/N) due to Incident |
Yes |
|
Fatalities (Number) |
0 |
|
Number of People Evacuated |
Unknown |
|
Number of Habitable Structures Evacuated |
1 |
|
Number of Habitable Structures Flooded |
0 |
|
Other Infrastructure Impacts |
|
|
Economic Damages (in $) |
Unknown |
|
Volume released at failure (ac-ft) |
|
|
Response |
Emergency pumping and partial removal of riser to clear blockage |
|
Additional Remarks or Updates |
|
|
Incident Time |
4:51 PM |
|
Incident Duration |
|
|
Incident Report Produced |
Yes |
|
Information Sources |
MD Dam Safety |
|
Owner Type |
P |
|
Dam Type |
RE |
|
Primary Purpose(s) |
C |
|
EAP |
Y |
|
Year Completed |
1961 |
|
Year Modified |
0 |
|
Dam Height |
10 ft |
|
Max Storage (ac-ft) |
48 ac-ft |
|
Surface Area (acres) |
0 acres |
|
River Name |
Antietam Creek-TR |
|
Latitude |
39.675 |
|
Longitude |
-77.723 |
|
Regulatory Agency(ies) |
MD Dam Safety |
|
NID Number |
MD00581 |
|
Attachments |
|